When thinking of a high-end coffee brewer that masters all the jacks of taste and quality, the Fetco Coffee brewer is probably the first hit in every coffee lover’s mind. The consistency and flavor take the coffee game to a whole new level. However, it often gets out of order if used incorrectly. So, do you want to learn about fetco brewer troubleshooting?
Fetco brewer troubleshooting is quite easy once you catch the culprit. In most cases, we haven’t assembled the brewer correctly or set it right. However, check your power supply before going for any other troubleshooting.
So, let’s buckle down through the article and find ways to bring our stuck fetco brewer back into working!
Why is my coffee machine not working? Fetco Brewer troubleshooting!
If your fetco coffee brewer is not out on the blink, here are some possible reasons. Here you will find the top 9 reasons that can be possible reasons for your fecto brewer not working. Let’s see the common reasons below:
- Brew Handle is not staying down
- Ready Light is Off
- The ready light is on
- Short Brew Levels
- High Brew Levels
- Brew Basket and Spray head Dripping
- Doesn’t Stop Brewing
- Too heavy or Too Light Coffee
- Fetco Coffee Brewer Error Codes
Fetco brewer troubleshooting: Problems and Solutions
Following are the possible solutions to the above-listed problems. So, let’s go through them.
Problem 1: Brew Handle is not staying down
If your coffee brew handle isn’t staying down, there are chances that either
- your power switch is off
- Dispense latch Assembly isn’t correct
- Bad timer
Solution:
So, first of all, start by checking the power supply. See if the machine is correctly plugged in or not. Then turn on the switch.
However, if your dispense latch assembly is at fault, then either the brewer light will keep on blinking or the brewer will buzz during the operation. In that case, you don’t have an option other than going for an authorized technician to replace it.
Lastly, if there is a bad timer, there is some issue due to which the required voltage isn’t reaching the timer. In that case, too, only a technician can help you out.
Problem 2: Ready Light is Off
If the light is off, the power isn’t reaching the thermostat. Maybe your liquid level control board is broken, thus preventing the power from reaching the thermostat. Maybe there is a malfunctioned part, leading to an open circuit connection.
Solution:
- Get the thermostat checked by a technician.
- Check if you have turned on the switch correctly.
Problem 3: Ready light is on
However, if your ready light is on, it means that you have a faulty thermostat (broken) or your temperature is set below 205°F.
Solution:
Raise the temperature to 205°F or above. Else replace the thermostat.
Problem 4: Short Brew Levels
If you are experiencing short brew levels, then there is a chance that you may have set the brewer’s time low. If that isn’t the case, then here are a few additional things to check out.
A. Maybe your flow discs are placed upside down.
Solution:
In that case, reassemble the discs correctly so that bumps on the cutter side face down along with the flange.
B. Either the spray head or water filter is clogged.
Solution:
In that case, replace them, and clean the brewer properly.
C. Lastly, check if there is proper voltage coming from the circuit breaker. Most of the time, users don’t know that it is not the brewer but the circuit that is causing the problem.
Problem 5: High Brew Levels
If your experience Hugh brew levels on every brew, then there is only one possibility: the timer is set too high.
Solution:
In that case, you need to set the timer to the correct level per your need.
However, if it occurs occasionally, you may haven’t emptied the dispenser correctly. Empty it out, and see if the problem prevails or not.
Problem 6: Brew Basket and Spray head Dripping
Sometimes, what happens is that the spray head or the Brew holder starts to drip.
A. It happens mostly due to condensation around the area.
Solution:
So, empty it down, and wipe the area with water.
B. Other than this, there are chances that your holder is cracked and the fill valve has become loose.
Solution:
So, in both cases, you must replace the respective parts with a new ones.
Problem 7: Doesn’t Stop Brewing
If the brewer doesn’t stop brewing, there are some possible reasons:
A. The water pressure is more than 75 psi.
Solution:
Lower it to somewhere between 20 to 70 psi
B. There is an issue with mechanical binding.
Solution:
Make sure that the brew handle, dispense tube, and sprayhead tower are in a straight line.
C. The water level probe or fill valve is broken.
Solution:
Replace it with a new one
- Maybe the liquid level control board is broken. For that purpose, contact an authorized technician.
Problem 8: Too heavy or Too Light Coffee
In that case, first of all, check if you are adding the right amount of ground coffee powder. If yes, then.
- Maybe the Brew levels aren’t correct. Adjust them accordingly.
- Sprayhead is not working correctly.
- The water tank level is not correct. Adjust it around 205°F.
Problem 9: Fetco Coffee Brewer Error Codes
Sometimes, an error code pops up soon after you operate the brewer. So, this section guides you through some most common error codes.
01. Internal Code (Code 001):
It shows that there is some problem internally in the control board.
So, you need to reprogram the settings, and your problem will get solved.
02. Shorted Temperature Probe (Code 050):
It means your probe is at fault and needs a replacement
03. Open Temperature Probe (Code 051):
It means that the probe is working, but there is some connection error.
04. Initial Fill Error (Code 100):
It occurs when more than 15 minutes have passed since the initial fill. The reason behind it is that the flow rate is too low. Maybe the filter is clogged. Give your brewer a thorough cleaning.
05. Refill Error (Code 101):
This error shows that the tanks haven’t been refilled within three minutes of emptying.
06. Unwanted Refill (Code 102):
It occurs when the fill valve remains activated for more than 30 seconds during a 1-hour operation.
07. Flat Line Temperature (Code 200):
The stated error occurs if you don’t raise the temperature after the brewer calls for heat.
08. Heart Short (Code 202):
The error results when the temperature rises even when the brewer doesn’t call for it.
09. Keypad Error (Code 255):
This error occurs if someone presses the keypad for more than 45 seconds.
So, these were some general troubleshooting and error codes taken from the fetco coffee brewer manual and fetco coffee brewer manual CBS 2052e. However, they can be guidelines for nearly all fetco brewers with a few exceptions.
Is Breville precision brewer troubleshooting the same as that of Fetco brewer?
Yes!
The troubleshooting of all the coffee Brewers is more or less the same, with a few exceptions.
However, the error codes are different.
Some of the common Breville precision brewer error codes are:
- Err1,Err2, Err4, Err5: Some internal issue
- Err7: Blockage or Clogging
- Err3: Unstable or no power supply
Top 3 fetco coffee brewers to buy!
Now that we are well abreast with the troubleshooting of fetco brewers, let’s find out the top 3 fetco coffee brewers. So, here they are:
01. CBS-2142 XTS Twin Station Coffee Brewer
It is a one-gallon brewer with two stations and a touchscreen interface that works ideally for medium-sized venues.
It is a low profile newer that is compatible with LUXUS thermal servers and dispensers.
02. CBS-2161 XTS Single Station Coffee Brewer
It is a 3-gallon brewer that works ideal for large venues like restaurants and cafeterias. Moreover, it has an easy-to-use, inviting interface with a touch screen.
03. CBS-51H-15 Handle-Operated Coffee Brewer
It has a 1.5 gallon (3.8 liters) capacity and features a dual brew Basket lock and gravity-fed dispense tube.
Best Coffee Brewer Online:
Frequently Asked Questions
How do brewers work?
Brewers are a type of coffee maker which uses the principles of gravity and pressure to move hot water through the powdered coffee beans and get a delicious cup of joe.
Is brewed coffee good for health?
Yes!
Brewed coffee is good for your health. 2 to 3 cups of brewed coffee helps to reduce the risk of heart attack, diabetes, and endometrial cancer.
How To Do A Breville Precision Brewer Factory Reset?
To factory reset your Breville precision brewer, follow the given steps:
01. Turn in the brewer
02. Press the power button and 1 cup button simultaneously and hold for seconds. 03. The display screen will say rSET.
04. Press Menu and click Factory Reset
05. The machine will beep three times, and the process will start.
How to troubleshoot error code 050?
The error code 050 means the probe is not working properly, and you need to replace the probe with a new one.
Conclusion
So, these are the few ways to troubleshoot your fetco brewer. First of all, detect the problem and then solve it accordingly.
However, if that doesn’t help you out, contact an authorized technician, and get your brewer back functioning. ENJOY THE HAPPY BREWING FELLOW!